Project Description

Overview

DC Electronic Load DC Electronic Load 1200 W- rear panel (3) front
  • The 66XX Series is a DC programmable power supply based on a high performance microprocessor.
  • High precision, low noise, low ripple, noise amplitude <3mV.
  • High resolution and accuracy of 0.1mV/0.01mA.
  • Built-in high precision 5 1/2 voltmeter and milliohm meter.
  • Intelligent fan system that adjusts fan speed based on temperature changes.

Features

  • 3.5 inch TFT screen display
  • Supports high precision and dynamic programming output
  • Load regulation test function
  • Chinese and English operation menu, powerful function
  • Support external trigger input and output
  • Support remote voltage compensation, multi data storage

Application

  • Laboratories and schools
  • Aerospace electronics applications
  • Power for chips and sensitive components
  • Power for automotive electronic components
  • Power for wireless communication

Specification

ModelHT 6611HT 6612HT6613
Rated outputVoltage0-30V0-75V0-150V
Current0-5A0-2A0-1A
Load regulationVoltage<0.01%+0.5mV<0.01%+0.5mV<0.01%+0.5mV
Current<0.01%+0.1mA<0.01%+0.1mA<0.01%+0.1mA
Setting Value ResolutionVoltage0.5mV1mV2mV
Current0.1mA0.05mA0.01mA
Readback Value ResolutionVoltage0.1mV0.1mV1mV
Current0.01mA0.01mA0.01mA
Setting Value AccuracyVoltage0.01%+2mV0.01%+5mV0.01%+10mV
Current0.05%+1mA0.05%+0.5mA0.05%+0.1mA
Readback Value AccuracyVoltage0.02%+5mV0.02%+15mV0.02%+35mV
Current0.1%+5mA0.05%+2mA0.05%+1mA
RippleVoltage3mvp-p5mvp-p10mvp-p
Current2mA rms1mA rms0.5mA rms
Voltmeter Accuracy0-12V accuracy 0.02%+2mV; 0-58V accuracy: 0.02%+6mV
Milliohmmeter Accuracy10W. 0-1000mΩ accuracy:0.2%+3mΩ; 1000-10000mΩ accuracy:0.2%+6mΩ
Working Condition0-40℃;0-90%RH
Power RequiredAC 120V/220V±10%; 50/60HZ
Weight
Dimension358*214*104
ModelHT 6651HT 6652HT6653
Rated outputVoltage0-6V0-30V0-75V
Current0-60A0-20A0-8A
Load regulationVoltage<0.01%+1mV<0.01%+1mV<0.01%+1mV
Current<0.01%+0.1mA<0.01%+0.1mA<0.01%+0.1mA
Setting Value ResolutionVoltage0.1mV0.5mV1mV
Current1mA0.5mA0.2mA
Readback Value ResolutionVoltage0.1mV0.1mV0.11mV
Current0.1mA0.1mA0.1mA
Setting Value AccuracyVoltage0.01%+1mV0.01%+5mV0.01%+10mV
Current0.05%+6mA0.05%+2mA0.05%+1mA
Readback Value AccuracyVoltage0.02%+2mV0.02%+5mV0.02%+15mV
Current0.05%+45mA0.05%+20mA0.05%+8mA
RippleVoltage3mvp-p5mvp-p7mvp-p
Current15mA rms7mA rms4mA rms
Voltmeter Accuracy0-12V accuracy 0.02%+2mV; 0-58V accuracy: 0.02%+6mV
Milliohmmeter Accuracy10W. 0-1000mΩ accuracy:0.2%+3mΩ; 1000-10000mΩ accuracy:0.2%+6mΩ
Working Condition0-40℃;0-90%RH
Power RequiredAC 120V/220V±10%; 50/60HZ
Weight
Dimension

Similar Models