With a maximum voltage of 3.5kV AC/4kV DC, DP7000 compact high-voltage wire/cable harness tester greatly reduces its size compared to the first generation high-voltage wire/cable harness tester. It also can be used for distributed high-voltage wire harness test.
DP7000 wire/cable harness tester is usually used in testing high-voltage connectors, cable, automotive power battery pack wiring harness, automotive PDU control box, as well as in testing AC/DC charging gun and AC/DC charging seat. Distributed DP7000 cable/wire harness tester is commonly used to test railway vehicle jumpers, electrical boxes, and cabins.
- Precise four-wire test measurement (equipped with contact verification of temperature compensation foolproof four wire fixture)
 - Support distributed testing, up to 20480 points
 - Mixed two-wire or four-wire test available
 - On-state resistance resolution 10μΩ
 - Voltage withstand test up to 3.5kV AC/4kV DC
 - LCR test frequency 50Hz~100kHz
 - Insulation test up to 10G Ω
 - Board modular design
 - A multifunctional IO board to achieve one-stop test in charging guns/PDUs
 
- Automatic grasping high-voltage points
 - Automatic self-learning for conduction points
 - Easy to understand settings and editing
 - Support bar code scan and print function
 - Local database and docking with MES
 - Multimeter offers point-to-point verification test
 - Device self-checking and automatic point finding, point alias naming
 - Prite report in PDF format
 - I/O interface customization
 - Safety grating to prevent electric shock (horizontal)
 - Support voice broadcast points and visually graphic edit
 
- Electric vehicles high-voltage cables and connectors test
 - Electric vehicle PDU test
 - AC/DC charging gun holder test
 - Rail transit distributed test
 - Military and nuclear cable/wire test
 
| Model | DP7000 | ||
| Measuring Mode | Inner four-wire + outer four-wire | ||
| Maximum number of test points | 192 | ||
| AC Output Voltage | 50-3.5kV AC | ||
| DC Output Voltage | 50-4kV DC | ||
| High Voltage Output Accuracy | ±3% | ||
| High Voltage Measurement Accuracy | ±3% | ||
| High Voltage Measurement Time | 0.02s – 60s, user delay not included | ||
| Low Voltage Measurement Time | 0.02s – 60s, user delay not included | ||
| O/S Measurement Time | 5mS (192 points, user delay not included) | ||
| Test items and range | O/S, Intermittence O/S, Quick Intermittence Open Circuit  | 
2kΩ-100 kΩ | |
| Inner Four-wire Test Conductance | 0.1Ω-1MΩ | ||
| Outer Four-wire Conductance Test | Measurement Range | 1μΩ-100Ω | |
| Current Signal | ≤1A | ||
| AC Hipot Leakage Current | 0.01mA-10mA | ||
| DC Hipot Leakage Current | 0.1μA-5mA | ||
| DC Hipot Insulation Resistance | 1MΩ-5GΩ | ||
| Measurement Range | 100mΩ-20MΩ | ||
| DC Resistance | Level Signal | 0-5V | |
| Current Signal | ≤10mA | ||
| Capacitances Measurement Range | 10pF-100mF | ||
| Resistance Measurement Range | 100mΩ-20MΩ | ||
| LCR | Inductance Measurement Range | 10nH~100H | |
| Frequency Signal | 50Hz/60Hz/100Hz/120Hz/1kHz/10kHz/100kHz | ||
| Range Mode | AUTO/HOLD | ||
| Level Signal | 0.1/0.3V/1V | ||
| Diodes/Zener diodes | Test Range | 0-80V | |
| Test Signal | 1mA/80V | ||
| Single-Side Test | Yes | ||
| O/S Terminal Judge | Yes | ||
| Advanced Functions | Programmable continuous test/ Automatic point search/ Auto-diagnosis | ||
| Test Scan Mode | Automatic/manual/external | ||
| Measurement Signal | low voltage measurement signal | ||
| Storage Memory | Number of test file up to 500 sets | ||
| OS Voltage | 5V | ||
| Panel | System/ Rapid/ Edit/ Function | ||
| Indicator | Pass/ Fail HV LED red-green indicator lights/ Screen Display/ Sound | ||
| Dimension (W*H*D) | 500*420*400 mm | ||
| Weight | 25 kg | ||
											
				