Project Description
The HT9815B programmable DC electronic load supports four mainstream operating modes: Constant Current (CC), Constant Voltage (CV), Constant Resistance (CR) and Constant Power (CP). It is equipped with comprehensive advanced test functions including automatic testing, dynamic load testing, over-current testing and timing sequence testing.
This instrument adopts a brand-new large touch screen combined with physical buttons and rotary knobs, solving the pain points of complicated parameter setup and cumbersome operation of traditional electronic loads. Users can rapidly configure complex test procedures and parameters without frequent page switching, which greatly improves test efficiency. The intuitive graphical interface effectively prevents parameter configuration errors.
Standard RS232 and RS485 communication interfaces are pre-installed for seamless integration into various automated test systems. An external IO trigger port is also reserved for connecting peripheral trigger signals.
- Four core operation modes: CC / CV / CR / CP
- Built-in automatic test & sequential list test functions
- Dynamic load response frequency up to 50kHz
- High measurement resolution: 0.1mV (voltage), 0.1mA (current)
- Dedicated battery test mode
- OCP over-current test & remote sense measurement function
- Built-in short-circuit simulation function
- Special CR mode optimized for LED testing
- Voltage & current ripple measurement capability
- Power-off parameter memory retention function
- Storage capacity for up to 100 groups of test parameter files
- Standard RS232 / RS485 communication ports
| Parameter | 1500W-500V-120A | ||
| Nominal Value | Power | 1500W | |
| Voltage | 0-50V | 0-500V | |
| Current | 0-12A | 0-120A | |
| Min op volt | 028V at 12A | ||
| 2.8V at 120A | |||
| CV Mode | Range | 0-50V | 0-500V |
| RES. | 0.1mV | 1mV | |
| Accuracy | ±(0.05%+0.03%FS) | ||
| CC Mode | Range | 0-12A | 0-120A |
| RES. | 0.1mA | 1mA | |
| Accuracy | ±(0.05%+0.05%FS) | ||
| CR Mode | Range | 0.047Ω~7.5KΩ | |
| RES. | 16bit | ||
| Accuracy | (0.1+0.01R)% | ||
| CW Mode | Range | 1500W | |
| RES. | 10mW | 0.1W | |
| Accuracy | ±(0.1%+0.2%FS) | ||
| DYNA | Time | 10uS-50S | |
| Accuracy | 2uS | ||
| Slope | 0.0003-3A/uS | ||
| MEAS RANGE | |||
| VOLT MEAS | Range | 0-50V | 0-500V |
| RES. | 0.1mV | 1mV | |
| Accuracy | ±(0.02%+0.03%FS) | ||
| CURR MEAS | Range | 0-12A | 0-120A |
| RES. | 0.01mA | 0.1mA | |
| Accuracy | ±(0.05%+0.05%FS) | ||
| POW MEAS | Range | 1500W | |
| RES. | 10mW | 0.1W | |
| Accuracy | ±(0.1%+0.2%FS) | ||
| PROTECT RANGE | |||
| OPP | ≈1500W | ||
| OCP | ≈12.6A | ≈126A | |
| OVP | ≈52.5V | ≈525V | |
| OTP | ≈85℃ | ||
| SHORT | CC | ≈12.6A | ≈126A |
| CV | ≈0.28~2.8V | ||
| CR | ≈20mΩ | ||
| INP RES | 500KΩ | ||
| SIZE&WEIGHT | |||
| SIZE(W*H*D) | 483mm*100mm*500mm | ||
| WEIGHT | 16.6kg | ||