Project Description
The HT9812D programmable DC electronic load features four standard operating modes: constant current (CC), constant resistance (CR), constant voltage (CV) and constant power (CP). It is further equipped with abundant advanced functions including auto-test, dynamic load test, over-current test and sequence timing test.
Adopting a new large touchscreen combined with physical keys and an adjustment knob, the device eliminates the complicated parameter setup and cumbersome operation of older models. Users can quickly configure complex test workflows and parameters without frequent interface switching, greatly improving testing efficiency, while the intuitive display reduces setup errors.
Standard communication interfaces RS232 and RS485 are pre-installed, enabling seamless integration into various automated test systems. An external IO trigger port is also reserved for external signal linkage.
- Four core operation modes: CC / CV / CR / CP
- Built-in auto-test & list sequence test functions
- Dynamic load frequency up to 50kHz
- High measurement resolution: 0.1mV for voltage, 0.1mA for current
- Dedicated battery test function
- OCP over-current test & remote sense measurement support
- One-key short-circuit simulation function
- CR mode specialized for LED drive testing
- Voltage & current ripple measurement function
- Power-off parameter memory retention
- Storage capacity for up to 100 groups of test profiles
- Standard RS232 & RS485 communication ports
| Parameter | 300W-500V-35A | ||
| Nominal Value | Power | 300W | |
| Voltage | 0-50V | 0-500V | |
| Current | 0-3.5A | 0-35A | |
| Min op volt | 0.25A at 3.5A | ||
| 3V at 35A | |||
| CV Mode | Range | 0-50V | 0-500V |
| RES. | 0.1mV | 1mV | |
| Accuracy | ±(0.05%+0.02%FS) | ±(0.05%+0.02%FS) | |
| CC Mode | Range | 0-3.5A | 0-35A |
| RES. | 0.01mA | 0.1mA | |
| Accuracy | ±(0.05%+0.05%FS) | ±(0.05%+0.05%FS) | |
| CR Mode | Range | 0.047Ω~7.5KΩ | |
| RES. | 16bit | ||
| Accuracy | (0.1+0.01R)% | ||
| CW Mode | Range | 300W | |
| RES. | 1mW | 10mW | |
| Accuracy | ±(0.1%+0.2%FS) | ||
| DYNA | Time | 10uS-50S | |
| Accuracy | 2uS | ||
| Slope | 0.0003-3A/uS | ||
| MEAS RANGE | |||
| VOLT MEAS | Range | 0-50V | 0-500V |
| RES. | 0.1mV | 1mV | |
| Accuracy | ±(0.025%+0.025%FS) | ||
| CURR MEAS | Range | 0-3.5A | 0-35A |
| RES. | 0.01mA | 0.1mA | |
| Accuracy | ±(0.05%+0.05%FS) | ||
| POW MEAS | Range | 300W | |
| RES. | 1mW | 10mW | |
| Accuracy | ±(0.1%+0.2%FS) | ||
| PROTECT RANGE | |||
| OPP | ≈315W | ||
| OCP | ≈3.51A | ≈35.1A | |
| OVP | ≈52.5V | ≈525V | |
| OTP | ≈85℃ | ||
| SHORT | CC | ≈3.51A | ≈35.1A |
| CV | ≈0.25~3V | ||
| CR | ≈80mΩ | ||
| INP RES | 500KΩ | ||
| SIZE&WEIGHT | |||
| SIZE(W*H*D) | 215mm*103mm*390mm | ||
| WEIGHT | 4.3kg | ||